Domain 1: Hydraulics and Pneumatics

Question 1

A pillow block bearing on a conveyor drive shaft begins running hot, and grease starts weeping past the seal, roughly two hours after a scheduled regrease. The MOST likely cause is:

Show answer & explanation

Correct answer: D - Excess grease is churning and generating heat

Question 2

A flexible jaw coupling between a motor and a pump has failed three times in eight months. Each replacement was installed per the manufacturer's instructions, and the unit operates within its rated load. The MOST likely underlying cause is:

Show answer & explanation

Correct answer: C - Shaft misalignment the coupling is being asked to absorb

Domain 2: Welding and Rigging

Question 3

A centrifugal pump that has run normally for months begins making a sound like gravel passing through the casing, and discharge flow has become erratic. The suction strainer was last cleaned eight months ago. The MOST likely cause is:

Show answer & explanation

Correct answer: A - Cavitation caused by restriction on the suction side

Domain 3: Power Transmission, Lubrication, Mechanical Maintenance, and Shop Machines, Tools & Equipment

Question 4

A conveyor motor starts when the START pushbutton is pressed but stops the instant the button is released. The motor runs normally while the button is held, and the overload has not tripped. The MOST likely fault is:

Show answer & explanation

Correct answer: C - The auxiliary seal-in contact has failed open

Domain 4: Pumps, Piping, and Combustion

Question 5

A double-acting hydraulic cylinder has a 4-inch bore and operates at 1,200 psi. What force does it develop on the extend stroke?

Show answer & explanation

Correct answer: B - 15,079 lb

Domain 5: Motors, Control Circuits, and Schematics & Print Reading

Question 6

A solenoid valve fails to actuate. At the PLC, the output module status LED for that address is illuminated, and the program shows the rung is true with no forces applied. The MOST logical next check is:

Show answer & explanation

Correct answer: D - The field wiring and the solenoid coil itself

Domain 6: Digital Electronics, Power Supplies, Computers & PLC, and Test Instruments

Question 7

Three 60-ohm heating elements are connected in parallel across a 120 V supply. What is the total resistance of the circuit?

Show answer & explanation

Correct answer: B - 20 ohms

Domain 7: Basic AC/DC Theory, Power Distribution, and Electrical Maintenance

Question 8

A 6,000 lb load is lifted with a two-leg bridle sling. Each leg forms a 30-degree angle with the horizontal. What is the approximate tension in EACH leg?

Show answer & explanation

Correct answer: C - 6,000 lb

More WMTA practice questions

Question 9

A medium-temperature system with a TXV shows 22°F of superheat and 18°F of subcooling. Head pressure is normal for the ambient conditions. This combination MOST likely indicates:

Show answer & explanation

Correct answer: D - A restriction in the liquid line

Question 10

A technician has notified affected employees, shut a machine down using its normal stopping procedure, locked open the disconnect, and bled the pneumatic supply. Under 29 CFR 1910.147, what must be done before the repair begins?

Show answer & explanation

Correct answer: A - Verify zero energy by attempting a normal start